    • Due to unforeseen circumstances, our phone line will be unavailable from 5pm to 9pm GMT on Thursday, 28th March. Please be assured that orders will continue to be processed as usual during this period. For any queries, you can still contact us through your customer portal, where our team will be ready to assist you.

      March 28, 2024

  • Sign In

Disclaimer: This is an example of a student written essay.
Click here for sample essays written by our professional writers.

Any scientific information contained within this essay should not be treated as fact, this content is to be used for educational purposes only and may contain factual inaccuracies or be out of date.

Carbon Fibre Composite

Paper Type: Free Essay Subject: Engineering
Wordcount: 472 words Published: 24th Apr 2017

Reference this

Strength of Laminated Fibrous Composites Lab

  • Summary

This report compares the results of theoretical calculations undertaken to predict the tensile strength of carbon fibre reinforced composites against experimental results. Two main methods for the calculation of tensile strength are used; the rule of mixtures and the ten percent rule. These standard theories appear to be valid for the majority of cases although inconsistencies are observed for the 90°, transversely loaded, isostress condition.

  • Aims
  • To become familiar with composite materials, their structure and quality
  • To understand how carbon fibre reinforced polymer, CFRP, materials are tensile tested
  • Objectives
  • To examine samples of composites and their precursors
  • Examine typical microstructure
  • Tensile test different samples of CFRP composites
  • Introduction

This work looks at the tensile strength of different structural make-ups of carbon fibre reinforced polymers. Carbon fibres have greatest strength when they are loaded in the isostrain (0°) condition as illustrated in Figure 4.1. In the isostrain condition, the majority of the applied load is transferred to the long fibre strands whereas in the isostress condition, the load is acting perpendicular to the fibre length and yields a far lower maximum strength. When there are multiple layers of fibres in the composite, orientated in different directions, otherwise known as a mixed ply lay-up, the maximum tensile strength varies with respect to the fibre angle.

Figure 4.1 – Composite Loading

Four different composite lay-up structures are looked at in this report. Each lay-up consists of a total of 16 layers which are symmetrical about the neutral axis. The layups of the composites are:

Where subscripts:

2, 4, 8 = multiple of layers noted in the brackets

S= refers to symmetry about the neutral axis

A – [ 0° ]8S

B – [ 90° ]8S

C – [ +45°,-45° ]4S

D – [0°/+45°/-45°/90°]2S

The test specimens consist of a section of CFRP with metal plates attached with epoxy resin at either end as shown later on in Figure 5.1. These metal plates are purely for clamping of the CFFP section into the in the tensile testing rig as shown in Figure 5.2.

  • Experimental Method

The dimensions of the test specimens are noted for each piece prior to any testing and will be used for fair comparison in the theoretical calculation methods. Dimensions for each specimen, A-D are shown below where x and y relate to the dimensions shown in Figure 5.1.

 

Cite This Work

To export a reference to this article please select a referencing stye below:

Reference Copied to Clipboard.
Reference Copied to Clipboard.
Reference Copied to Clipboard.
Reference Copied to Clipboard.
Reference Copied to Clipboard.
Reference Copied to Clipboard.
Reference Copied to Clipboard.

Related Services

View all

DMCA / Removal Request

If you are the original writer of this essay and no longer wish to have your work published on UKEssays.com then please: